First thing to check is the cord. . Why You Should Only Work With A Qualified Professional. Verify salinity with Myron L meter calibrated for NaCl, titration test units, or other salt meters. Methods: A cross-sectional observational study was performed in the Intoxication Control Center of the Sao Paulo City Hospital. Must be picked up in our Moorpark, Ca location to qualify for the Jandy limited warranty. It may not display this or other websites correctly. ), PURE1400 - 1.25 lb./24 Hr. You need to determine the correct Revisio, Q: Do Not Sell or Share My Personal Information. The controller will periodically change the direction of the cell current in order to eliminate the layers of scale that deposit on the electrode plates. I have upgraded the circuits boards as per Zodiac's support advice and they only made the problem less prevalent. Adjust total alkalinity to 80-120ppm. If more chlorine is needed, activating the Boost mode will override this cold water feature allowing chlorine production for 24 hours of operation. App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. Any new postings here are unlikely to be seen or responded to by other members. In this thread, the amperage of the 1400 cell tests at about 5.6 amps, and the amperage of the 700 cell should test at about 2.8 amps.[11]. Some members add dielectric grease to the pins when they do their annual work on the filter and check the cell. The mineral purifier cartridge may have ruptured. Thanks, Problem solved. With the AquaPure 1400, the reading is in grams per liter, which is the same as 1,000 ppm. Please try again. Jandy no longer supports parts for their older systems. The preferred salt is an evaporated, granulated, food quality, non-iodized salt. If the unit does not read 2.8 gpl for salinity, then the unit has been recalibrated. On the other hand if the readings are different then it indicates that there is a problem with the board. Jul 7, 2021. The control center is connected with the pool circulation pump electrical source so that the electrolytic cell can only operate when the pool pump is on. This page was last edited on 21 November 2022, at 19:29. You are using an out of date browser. The Jandy AquaPure salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. The LCD display on the user interface offers monitoring of chlorine production, cell modes, salinity level, temperature, water flow and diagnostics. Sorry, we were unable to perform your search at this time. In Store Only. AquaPure Electronic Salt Water Chlorinator & PureLink Water Purification System Power Center & Cell Kit Installation & Operation Manual, AquaPure and PureLink Tri-Sensor Replacement Kits. If the Aquapure is disconnected from the Aqualink, then you should be able to set chlorine production from the front panel on the Aquapure. The cartridge must be replaced. I chose the Zodiac PLC1400 to pair with it. Page 17 in the Jandy Power Center Installation Manual shows the location of the jumper. If the readings are correct then the board is O.K. Guess we will this year. See Sections 6.4 of the owner's manual. A great system, easy to install. Drop in the Best When You Replace the Rest. The only hiccup we get, is an occasional communication error. The only difference is the new part has a ground wire that was attached to the common ground.[15]. It is ok to startup the chlorinator when there is a little bromide in the pool. Your question might be answered by sellers, manufacturers, or customers who bought this product. When the proper reading is reached press the Temperature button within 5 seconds to store it in memory. good documentation. Disconnect the flow salinity temp sensor from the board. Please select a nearby store with available inventory to process your order. For a better experience, please enable JavaScript in your browser before proceeding. Find a Dealer AquaPure Salt Water Pool System Downloads Document ID SL6605 It displays the salt level in PPM on the display, and you can set the production rate (0-100%) on the LCD display, or you can integrate the system with a Jandy controller as I did. If chlorine output at the lowest setting consistently provides for excessive chlorine levels, decrease daily pump operation time as much as necessary. I am concerned that this will affect Freeze Protect mode this winter. Press and hold the test buttons marked salinity and R-temp. You can usually see evidence of a leak when you know to look for it. The system will display the salinity reading, press the up arrow to increase the reading and the down arrow to decrease the reading. I bought one of these units from another vendor three years ago. Plug flow/temp/salinity sensor into connector on power center printed circuit board. 2 - Screws, Power Interface. 99. How does Aqualink RS Manage Solar and Gas Heating, Jandy IAqualink WiFi module with PDA Remote, iAqualink freeze protection - two specific questions, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Note that the center prong is on the cell where the power cord connects to the cell. The LCD should read 2.8 gpl*. It's cheaper to go with another salt unit if you are replacing the old Jandy unit, as was my case. If the actual salinity is above 4.0 gpl (4,000 ppm), the pool needs to be diluted to get the level below 4.0 gpl. Check connector at white plug to insure proper connection. The center prong is the most common point of failure. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. If its 02110A10 or 01220A15, you use program A, otherwise you use program B on the in-line module on the trisensor cord. This could be a defective automatic timer or pump switch or loose connection at the automatic timer or pump switch. 624537. ORP / External Control Interface 2. We will contact you as soon as this product is available. Haha! Low salt concentration below 2.0 gpl will cause premature cell failure. Do Not use Rock salt (insoluble impurities mixed with the rock salt can shorten the life of the unit). Apple is not a participant or sponsor of this promotion. We had to replace the filter and pump body! Here's another item of interest from p 877: IMPORTANT NOTICE NO WARRANTY if purchased online. NOTE: To clean the deposit (scale) on the electrolytic cell plates, see Section 6.3 of the owner's manual. Provide your account email address to receive an email to reset your password. See wiring diagram in Figures 2a, 2b, and 2c of the owner's manual. Aqualink prevents the Aquapure system from proper operation without a functioning water temperature signal from the Aqualink stand alone water temperature sensor, regardless of what the SWG flow sensor says. Rely on its sturdy design and simple features to create your saltwater oasis. 4.5 out of 5 stars 354 $ 1,098. If the cell is old, just get the PLC1400 kit. Either a short wait or a reboot resolve this. I couldn't get one of the screws on the power panel off, Help Support TFP Trouble Free Pool is run by a dedicated group of volunteers that Read more, Hello , This is an inactive thread. Jandy AquaPure control center for Jandy AquaPure PLC1400 and PLC700 chlorine generator cells. Remove cell for inspection. Use a salt that is at least 99.8% pure NaCl. Look for heavy corrosion at both ends. You can sometimes fix it by cleaning off the corrosion.[10]. Item No. It appears that Aqualink stops talking to Aquapure when the Aqualink water temperature sensor is inoperative.[12]. Do I still need to use granular chlorine with my Salt water chlorinator? Brand new! The salt water chlorinator replaces the hassle of having to use granular chlorine. For all your hard to find pool and spa parts, including above ground spa parts, , Copyright 2023 Pool and Spa Parts Depot. Test salinity. Then the Aquapure system will be connected to your Aqualink system. PLC1400 (Cell Kit), Dolphin Above Ground Robotic Pool Cleaners, Dolphin Residential Robotic Pool Cleaners, Solar Cover Blankets - Above Ground Pools, Utility Company Rebates for Pool Equipment, Kreepy Krauly Pool Cleaners Above Ground Pools, Kreepy Krauly Pool Cleaners Inground Ground Pools, Polaris Pool Cleaners - Above Ground Pools, Pentair Above Ground Pool and Spa Pool Heaters, Pentair Master Temp Inground Pool and Spa Heaters, Raypak Pool and Spa Heaters Gas and Propane, Hayward Commercial Thermoplastic Pump HCP Series, Hayward DEP 500 Series Pleated Element D.E. The cell cannot be repaired even though the plates may have life left in them. AquaPure Electronic Salt Water Chlorinator & PureLink Water Purification System Power Center & Cell Kit Installation & Operation Manual. Air, pool water, and SWG pool water. For a better experience, please enable JavaScript in your browser before proceeding. Super Chlorinate Pool. Salt only needs to be added when necessary. This site is protected by reCAPTCHA and the Google. We made the decision to go to a salt water pool system. From the Jandy controller, you can see the salt PPM, and you get a menu for setting the production rate percent for pool and spa modes - perfect. You know what? Adjusting the audible alarm volume is also described on page 34 of the Installation Manual. You use the% generation control to adjust the actual amount of chlorine generated to meet your pools chlorine need. Avoid using salt with anti-caking agents (sodium ferrocyanide, also known as YPS or yellow prussiate of soda) that could cause some discoloration of fittings and surface finishes in pool. Jandy Zodiac AquaPure PLC1400 PLC 1400 Saltwater Cell Kit AQUA PURE. They are built of a rugged glass-filled polypropelene material, have standard Jandy unions, and are NSF listed for your commercial application. The Jandy AquaPure, PureLink & Nature Fusion Soft Workbook gives a lot of good information on installation and troubleshooting. Apple is not a participant or sponsor of this promotion. The basic Jandy Aqualink RS System involves FIVE key elements: 1) Order your System Level. Plug in flow/temp/salinity sensor. ORP / External Control Interface 2. Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. (Cycle Power). So it looks like it is good, but the water temp sensor is bad. >PoolAndSpaPartsDepot.com is Open for Business! Why You Should Only Work With A Qualified Professional. If removing the cell is desired so that water may circulate without the cell, specialized plumbing would need to be added during installation of the cell. When the cell needs replacement you should replace the cell, tri sensor, and power cord. 21. Thank you for your business! Test salinity by pressing the Test Salinity button. Press and release the Temperature button within 5 seconds to enter the salinity calibration screen. Unit came with panel knocked out and the circuit board was bad. Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. Drop in the Best When You Replace the Rest. Is this unit a compatible replacement for an Aquapure 1400 control? Sorry - Air temperature sensor. This aquapure is use with PLC700 or PLc1400 for salt system only. View More Details. If the ladder is bonded properly to the rest of the pool equipment, corrosion will be minimal. In the case of a salt water chlorinator, the salt may damage the stone along the water line over time (crystallization). 2023 Zodiac Pool Systems LLC - All rights reserved. Sign up for regular updates and to get the Jandy Drop-In Replacement Guide for model comparisons, dimensions, and more. Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115 / 230 VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1. I've had a Jandy Aquapure 1400 since I opened the pool 4 years ago, and it's in the process of dying. Older Power Centers use a rectangle transformer P/N T1005 that is no longer available. To Enter Boost Mode Press and Hold Temperature Button 10 Seconds, Here is an excerpt from page 423 (892)[6] of their 2019 catalog:[7], "This Jandy Limited Warranty does not apply to Jandy branded products purchased through the Internet or other e-commerce platforms, with the exception of Jandy branded valves, parts, and accessories. See Section 5 of the owner's manual, Operating Instructions. Scale formation on pool equipment. However there is a jumper on the Power Interface Board that is connected for the 1400 cell and cut for the 700 cell. Adjust CHLORINE PRODUCTION to desired percentage. Had to down load from another site. Filter, Hayward Star-Clear Cartridges C-250 thru C-1750, Hayward Swim Clear Large Capacity Cartridges, Pentair Purex Bottom Manifold Filter Grids, Pentair Replacement Cartridges QUAD Filters, Filter Backwash Valves, Diverter Valves, Check Valves, Hayward Navigator - PoolVac Cleaner Parts, Pool Control Systems and Automation Parts, Aquarite Cell Replacements - Above Ground, Hayward Aquarite Goldline Parts, Sensors, Boards, Jandy Zodiac Salt Cell PLC1400 Aquapure1400 PureLink Cell Kit 40K, Jandy PLC700 PureLink 7-Blade Salt Generator Cell Kit, Hayward Salt & Swim 3C Control Unit Only W3SAS-PRO, Hayward Salt & Swim 3C Replacement Salt Cell W3SAS-CELL, Pentair IntelliChlor Salt Generator Above Ground Pools IC15 EC-520888, SmartSalt Salt Chlorine Generator 25K 25,000 Gallons, Hayward AquaTrol RJ Salt Chlorine Generator W3AQ-TROL-RJ, Pentair Intellichlor IC60 Salt Water System 521105 and 520556. Or just the control box? ORP / External Control Interface 2. An optional "Spool" Piece (sold separately) used to be available to replace the cell during winterizing or cell maintenance. Where to buy Jandy AquaPure Power Center. You can recalibrate the unit if you are really sure about the actual salinity and you want the box to match your readings.
Ricky Smith Storage Wars Age, Britax One4life Crash Test Consumer Reports, Articles J